Showing 5137–5148 of 18231 results
-
Product Name: Inverter.
Model: ACS800-01-0175-7.
UN ACS800-01-0175-7 = 690 V (Range 525 to 690 V). The power ratings are valid at ACS800-01-0175-7 nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 166A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 245A.
Typical motor power in no-overload use: 160KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 131A.
Typical motor power in heavy-duty use: 110KW.
Typical motor power in light-overload use: 132Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Frame size: R6.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg. -
Product Name: Inverter.
Model: ACS800-01-0205-3.
UN ACS800-01-0205-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0205-3 nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 290A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 351A.
Typical motor power in no-overload use: 160KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 234A.
Typical motor power in heavy-duty use: 132KW.
Frame size: R6.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 285A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg. -
Product Name: Inverter.
Model: ACS800-01-0205-5.
UN ACS800-01-0205-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0205-5 nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg. -
Product Name: Inverter.
Model: ACS800-01-0205-7.
UN ACS800-01-0205-7 = 690 V (Range 525 to 690 V). The power ratings are valid at ACS800-01-0205-7 nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 190A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 245A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 180A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 147A. -
Product Name: Inverter.
Model: ACS800-01-0255-5.
UN ACS800-01-0255-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0255-5 nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 290A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 351A.
Typical motor power in no-overload use: 200KW
Frame size: R6.
Typical motor power in light-overload use: 200Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 234A.
Typical motor power in heavy-duty use: 160KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 285A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg. -
Model: AD51-S3.
Basic program execution unit
Programming AD51-S3 language: GPC-BASIC (interpreter), number of tasks: 8
RS-232: AD51-S3 2-Channel, RS-422: 2 Channels.
Size: 250(H)×76(W)×113.5(D)mm.
Weight: 1.1kg. -
Model: AD51H-S3.
Basic program execution unit
Programming AD51H-S3 language: AD51H-BASIC (interpreter, compiler)
Task Number: AD51H-S3 8
RS-232: 2-Channel, RS-422: 1 channel, parallel interface: 1 channel, memory card interfaces: 2 slots
Size: 250(H)×76(W)×113.5(D)mm.
Weight: 0.9kg. -
Model: AD57.
Character generator editing, printing, AD57 editing CRT display canvas.
Switchable AD57 characters × 10 lines / 40 × 20 lines of 80 characters.
Size: 250 x 118 x 38MM.
Weight: 0.7kg. -
Model: AD57-S1.
Character generator editing, AD57-S1 printing, editing CRT display canvas.
80 characters × 20 lines.
Size: AD57-S1 250 x 118 x 38MM.
Weight: 0.7kg. -
Model: AD57-S2.
A6MD AD57-S2 only monitor display control unit. -
Model: AD59.
Memory Card / Centronics interface AD59 module.
Memory card interface, parallel interface (Centronics).
Size: AD59 250(H)×37.5(W)×113.5(D)mm.
Weight: 0.60kg. -
Model: AD59-S1.
Memory Card / Centronics interface AD59-S1 module.
Memory card interface (AD59-external MEF), a parallel AD59-S1 interface (Centronics)Size: 250(H)×37.5(W)×113.5(D)mm.
Weight: 0.51kg.