  • Product Name: Inverter.
    Model: ACS800-01-0070-2.
    UN ACS800-01-0070-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0070-2 nominal voltage 230 V.
    Frame size: R6.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
    Typical motor power in no-overload use: 55KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 184A.
    Typical motor power in light-overload use: 55Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
    Typical motor power in heavy-duty use: 37KW.
    Rated current available continuously without overloadability at 40 °C: 202A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0070-5.
    UN ACS800-01-0070-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0070-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 96A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
    Typical motor power in heavy-duty use: 45KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 88A.
    Typical motor power in light-overload use: 55Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
    Typical motor power in no-overload use: 55KW
    Frame size: R5.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0070-7 ACS800-01-0070-7.
    UN = 690 V (Range 525 to 690 V). The power ACS800-01-0070-7 ratings are valid at nominal voltage 690 V.
    Rated current available continuously without overloadability at 40 °C: 79A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 104A.
    Typical motor power in no-overload use: 75KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 73A.
    Typical motor power in light-overload use: 55Kw.
    Frame size: R6.
    Typical motor power in heavy-duty use: 45KW.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 54A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0100-3.
    UN ACS800-01-0075-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0075-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 166A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 202A.
    Typical motor power in no-overload use: 90KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.
    Typical motor power in light-overload use: 75Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Typical motor power in heavy-duty use: 55KW.
    Frame size: R6.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 115A.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0100-7.
    Frame ACS800-01-0100-7 size: R6.
    Rated current available continuously without overloadability ACS800-01-0100-7 at 40 °C: 93A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 124A.
    Typical motor power in no-overload use: 90KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 86A.
    Typical motor power in light-overload use: 75Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 62A.
    Typical motor power in heavy-duty use: 55KW.
    UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0105-5.
    UN ACS800-01-0105-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0105-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 145A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 170A.
    Typical motor power in no-overload use: 90KW
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Typical motor power in light-overload use: 90Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 100A.
    Typical motor power in heavy-duty use: 55KW.
    Frame size: R5.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 141A.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0120-3 ACS800-01-0120-3.
    UN = 400 V (Range 380 to 415 V). The power ACS800-01-0120-3 ratings are valid at nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 202A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
    Typical motor power in no-overload use: 110KW
    Frame size: R6.
    Typical motor power in light-overload use: 90Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
    Typical motor power in heavy-duty use: 75KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 184A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0120-5.
    UN ACS800-01-0120-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0120-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 157A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 202A.
    Typical motor power in no-overload use: 90KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 145A.
    Frame size: R6.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 113A.
    Typical motor power in heavy-duty use: 75KW.
    Typical motor power in light-overload use: 90Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0120-7.
    UN ACS800-01-0120-7 = 690 V (Range 525 to 690 V). The power ratings are valid at ACS800-01-0120-7 nominal voltage 690 V.
    Rated current available continuously without overloadability at 40 °C: 113A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 172A.
    Typical motor power in no-overload use: 110KW
    Frame size: R6.
    Typical motor power in light-overload use: 90Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 86A.
    Typical motor power in heavy-duty use: 75KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 108A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0140-5.
    UN ACS800-01-0140-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0140-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 180A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
    Frame size: R6.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 163A.
    Typical motor power in light-overload use: 110Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
    Typical motor power in heavy-duty use: 90KW.
    Typical motor power in no-overload use: 110KW
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0165-3 ACS800-01-0165-3.
    UN = 400 V (Range 380 to 415 V). The power ACS800-01-0165-3 ratings are valid at nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 260A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
    Typical motor power in no-overload use: 132KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
    Typical motor power in heavy-duty use: 110KW.
    Frame size: R6.
    Typical motor power in light-overload use: 132Kw.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0165-5.
    UN ACS800-01-0165-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0165-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 225A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
    Typical motor power in no-overload use: 132KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 220A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 163A.
    Typical motor power in heavy-duty use: 110KW.
    Frame size: R6.
    Typical motor power in light-overload use: 132Kw.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.