  • Product Name: Inverter.
    Model: ACS800-01-0030-5.
    UN ACS800-01-0030-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0030-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 42A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
    Typical motor power in no-overload use: 22KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 39A.
    Frame size: R4.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
    Typical motor power in heavy-duty use: 18.5KW.
    Typical motor power in light-overload use: 22Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0030-7 ACS800-01-0030-7.
    UN = 690 V (Range 525 to 690 V). The power ACS800-01-0030-7 ratings are valid at nominal voltage 690 V.
    Rated current available continuously without overloadability at 40 °C: 33A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 44A.
    Typical motor power in no-overload use: 30KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 30A.
    Frame size: R4.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 22A.
    Typical motor power in heavy-duty use: 18.5KW.
    Typical motor power in light-overload use: 22Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0040-2.
    UN ACS800-01-0040-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0040-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 103A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
    Typical motor power in no-overload use: 30KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 94A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
    Typical motor power in heavy-duty use: 18.5KW.
    Frame size: R5.
    Typical motor power in light-overload use: 22Kw.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0040-3.
    UN ACS800-01-0040-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0040-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 72A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
    Typical motor power in no-overload use: 37KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 69A.
    Typical motor power in light-overload use: 30Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Typical motor power in heavy-duty use: 22KW.
    Frame size: R5.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 49A.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0040-5.
    UN ACS800-01-0040-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0040-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 48A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 72A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 44A.
    Typical motor power in light-overload use: 30Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 36A.
    Typical motor power in heavy-duty use: 22KW.
    Frame size: R4.
    Typical motor power in no-overload use: 30KW
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0040-7.
    UN ACS800-01-0030-7 = 690 V (Range 525 to 690 V). The power ratings are valid at ACS800-01-0030-7 nominal voltage 690 V.
    Rated current available continuously without overloadability at 40 °C: 36A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 54A.
    Typical motor power in no-overload use: 30KW
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Typical motor power in light-overload use: 30Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 27A.
    Typical motor power in heavy-duty use: 22KW.
    Frame size: R4.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 34A.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0050-2.
    UN ACS800-01-0050-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0050-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 141A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 164A.
    Typical motor power in no-overload use: 37KW
    Frame size: R6.
    Typical motor power in light-overload use: 37Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 97A.
    Typical motor power in heavy-duty use: 30KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 132A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0050-3.
    UN ACS800-01-0050-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0050-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 86A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 112A.
    Typical motor power in no-overload use: 45KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 80A.
    Frame size: R5.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
    Typical motor power in heavy-duty use: 30KW.
    Typical motor power in light-overload use: 37Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0050-5.
    UN ACS800-01-0050-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0050-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 65A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
    Typical motor power in no-overload use: 37KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 61A.
    Typical motor power in light-overload use: 37Kw.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Typical motor power in heavy-duty use: 30KW.
    Frame size: R5.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 50A.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0060-2.
    UN ACS800-01-0060-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0060-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 166A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 202A.
    Typical motor power in no-overload use: 45KW
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
    Typical motor power in light-overload use: 45Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 115A.
    Typical motor power in heavy-duty use: 30KW.
    Frame size: R6.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.

  • Product Name: Inverter.
    Model: ACS800-01-0060-3.
    UN ACS800-01-0060-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0060-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 103A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
    Typical motor power in no-overload use: 55KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 94A.
    Typical motor power in light-overload use: 45Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
    Frame size: R5.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Typical motor power in heavy-duty use: 37KW.

  • Product Name: Inverter.
    Model: ACS800-01-0060-5.
    UN ACS800-01-0060-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0060-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 79A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 112A.
    Typical motor power in no-overload use: 45KW
    Frame size: R5.
    Typical motor power in light-overload use: 45Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
    Typical motor power in heavy-duty use: 37KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 75A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.