Showing 5089–5100 of 18231 results

  • Product Name: Inverter.
    Model: ACS800-01-0005-5.
    UN ACS800-01-0005-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0005-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 6.2A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
    Typical motor power in no-overload use: 3KW
    Frame size: R2.
    Typical motor power in light-overload use: 3Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.2A.
    Typical motor power in heavy-duty use: 2.2KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 5.6A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0006-2.
    UN ACS800-01-0006-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0006-2 nominal voltage 230 V.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 24A.
    Typical motor power in no-overload use: 4KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 18A.
    Typical motor power in light-overload use: 4Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 14A.
    Typical motor power in heavy-duty use: 3KW.
    Frame size: R3.
    Rated current available continuously without overloadability at 40 °C: 19A
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0006-3.
    UN ACS800-01-0006-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0006-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 10.9A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
    Typical motor power in no-overload use: 4KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
    Typical motor power in light-overload use: 4Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
    Typical motor power in heavy-duty use: 3KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0006-5.
    UN ACS800-01-0006-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0006-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 8.1A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
    Typical motor power in no-overload use: 4KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
    Typical motor power in light-overload use: 4Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.6A.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Typical motor power in heavy-duty use: 3KW.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0009-2.
    UN ACS800-01-0009-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0009-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 25A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
    Typical motor power in no-overload use: 5.5KW
    Frame size: R3.
    Typical motor power in light-overload use: 5.5Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
    Typical motor power in heavy-duty use: 4KW.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 24A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0009-3 ACS800-01-0009-3.
    UN = 400 V (Range 380 to 415 V). The power ACS800-01-0009-3 ratings are valid at nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 13.9A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.
    Typical motor power in no-overload use: 5.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12.7A.
    Typical motor power in light-overload use: 5.5Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.3A.
    Typical motor power in heavy-duty use: 4KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0009-5.
    UN ACS800-01-0009-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0009-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 10.5A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
    Typical motor power in no-overload use: 5.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10A.
    Typical motor power in light-overload use: 5.5Kw.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
    Typical motor power in heavy-duty use: 4KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.56A.

  • Product Name: Inverter.
    Model: ACS800-01-0011-2.
    UN ACS800-01-0011-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0011-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 34A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
    Typical motor power in no-overload use: 7.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 31A.
    Typical motor power in light-overload use: 7.5Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 23A.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
    Frame size: R3.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Typical motor power in heavy-duty use: 5.5KW.

  • Product Name: Inverter.
    Model: ACS800-01-0011-3.
    UN ACS800-01-0011-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0011-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 19A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 24A.
    Typical motor power in no-overload use: 7.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 18A.
    Typical motor power in light-overload use: 7.5Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 14A.
    Typical motor power in heavy-duty use: 5.5KW.
    Frame size: R3.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0011-5 ACS800-01-0011-5.
    UN = 500 V (Range 380 to 500 V). The power ACS800-01-0011-5 ratings are valid at nominal voltage 500 V.
    Frame size: R2.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.
    Typical motor power in no-overload use: 7.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12A.
    Typical motor power in light-overload use: 7.5Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.2A.
    Typical motor power in heavy-duty use: 5.5KW.
    Rated current available continuously without overloadability at 40 °C: 13.2A.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0011-7.
    UN ACS800-01-0255-5 = 690 V (Range 525 to 690 V). The power ratings are valid at ACS800-01-0255-5 nominal voltage 690 V.
    Rated current available continuously without overloadability at 40 °C: 13A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 14A.
    Typical motor power in no-overload use: 11KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 11.5A.
    Frame size: R4.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 8.5A.
    Typical motor power in heavy-duty use: 5.5KW.
    Typical motor power in light-overload use: 7.5Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0016-3.
    UN ACS800-01-0016-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0016-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 25A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
    Typical motor power in no-overload use: 11KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 24A.
    Frame size: R3.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
    Typical motor power in heavy-duty use: 7.5KW.
    Typical motor power in light-overload use: 11Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.