Showing 5077–5088 of 18231 results

  • Product Name: Inverter.
    Model: ACS550-01-526A-4.
    3-phase ACS550-02-526A-4 supply voltage 380 to 480 V.
    Typical motor ACS550-02-526A-4 power in 460 V at heavy-duty use: 400HP.
    Typical motor power in 400 V at normal use: 280kw.
    Typical motor power in 460 V at normal use: 450hp.
    Continuous rms current. 10% overload is allowed for one minute in ten minutes: 526A.
    Typical motor power in 400 V at heavy-duty use: 250KW.
    Free-standing units.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 477A.
    Frame size: R8.

  • Product Name: Inverter.
    Model: ACS550-01-602A-4.
    3-phase ACS550-02-602A-4 supply voltage 380 to 480 V.
    Free-standing units.
    Typical ACS550-02-602A-4 motor power in 400 V at normal use: 315kw.
    Frame size: R8.
    Continuous rms current. 10% overload is allowed for one minute in ten minutes: 602A.
    Typical motor power in 400 V at heavy-duty use: 280KW.
    Typical motor power in 460 V at heavy-duty use: 450HP.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 515A.
    Typical motor power in 460 V at normal use: 500hp.

  • Product Name: Inverter.
    Model: ACS550-01-645A-4.
    Typical ACS550-02-645A-4 motor power ACS550-02-645A-4 in 460 V at heavy-duty use: 500HP.
    Free-standing units.
    Typical motor power in 400 V at normal use: 355kw.
    Typical motor power in 460 V at normal use: 500hp.
    Continuous rms current. 10% overload is allowed for one minute in ten minutes: 645A.
    Typical motor power in 400 V at heavy-duty use: 315KW.
    3-phase supply voltage 380 to 480 V.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 590A.
    Frame size: R8.

  • Product Name: Inverter.
    Model: ACS800-01-0001-2.
    UN ACS800-01-0001-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0001-2 nominal voltage 230 V.
    Frame size: R2.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
    Typical motor power in no-overload use: 1.1KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.7A.
    Typical motor power in light-overload use: 0.75Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
    Typical motor power in heavy-duty use: 0.55KW.
    Rated current available continuously without overloadability at 40 °C: 5.1A
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0002-2.
    UN ACS800-01-0002-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0002-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 6.5A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
    Frame size: R2.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 6.0A.
    Typical motor power in light-overload use: 1.1Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.3A.
    Typical motor power in heavy-duty use: 0.75KW.
    Typical motor power in no-overload use: 1.5KW
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0003-2.
    UN ACS800-01-0003-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0003-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 8.5A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
    Typical motor power in no-overload use: 1.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
    Typical motor power in light-overload use: 1.5Kw.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Typical motor power in heavy-duty use: 1.1KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0003-3.
    UN ACS800-01-0003-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0003-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 5.1A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
    Typical motor power in no-overload use: 1.5KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.7A.
    Typical motor power in light-overload use: 1.5Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
    Typical motor power in heavy-duty use: 1.1KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0004-2.
    UN ACS800-01-0004-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0004-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 10.9A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Typical motor power in light-overload use: 2.2Kw.
    Typical motor power in no-overload use: 2.2KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
    Phd: 13.8A.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
    Typical motor power in heavy-duty use: 1.5KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0004-3 ACS800-01-0004-3.
    UN = 400 V (Range 380 to 415 V). The power ACS800-01-0004-3 ratings are valid at nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 6.5A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
    Typical motor power in no-overload use: 2.2KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 5.9A.
    Typical motor power in light-overload use: 2.2Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 1.3A.
    Typical motor power in heavy-duty use: 1.5KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0004-5.
    UN ACS800-01-0004-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0004-5 nominal voltage 500 V.
    Rated current available continuously without overloadability at 40 °C: 4.9A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
    Typical motor power in no-overload use: 2.2KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.5A.
    Typical motor power in light-overload use: 2.2Kw.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Typical motor power in heavy-duty use: 1.5KW.
    Frame size: R2.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0005-2.
    UN ACS800-01-0005-2 = 230 V (Range 208 to 240 V). The power ratings are valid at ACS800-01-0005-2 nominal voltage 230 V.
    Rated current available continuously without overloadability at 40 °C: 13.9A
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.
    Typical motor power in no-overload use: 3KW
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    Typical motor power in light-overload use: 3Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.3A.
    Typical motor power in heavy-duty use: 2.2KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12.7A.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

  • Product Name: Inverter.
    Model: ACS800-01-0005-3.
    UN ACS800-01-0005-3 = 400 V (Range 380 to 415 V). The power ratings are valid at ACS800-01-0005-3 nominal voltage 400 V.
    Rated current available continuously without overloadability at 40 °C: 8.5A.
    Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
    Typical motor power in no-overload use: 3KW
    Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
    Typical motor power in light-overload use: 3Kw.
    Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
    Typical motor power in heavy-duty use: 2.2KW.
    Frame size: R2.
    ACS800-01 without cable connection box does not ful? ll IP21 requirements.
    In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
    In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.