Showing 5029–5040 of 18231 results

  • Product Name: Inverter.
    Model: ACS355-01X-07A5-2.
    1-phase ACS355-01X-07A5-2 AC supply, 200 to 240 V.
    This code states the factory ACS355-01X-07A5-2 installed SW variants to the drive.
    Typical motor power in 460 V at normal use: 2.0hp.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 7.5A.
    Frame size: R2.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Typical motor power in 400 V at normal use: 1.5kw.

  • Product Name: Inverter.
    Model: ACS355-01X-09A8-2.
    1-phase ACS355-01X-09A8-2 AC supply, 200 to 240 V.
    Typical motor ACS355-01X-09A8-2 power in 400 V at normal use: 2.2kw.
    This code states the factory installed SW variants to the drive.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 9.8A.
    Frame size: R2.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Typical motor power in 460 V at normal use: 3.0hp.

  • Product Name: Inverter.
    Model: ACS355-03X-01A2-4.
    3-phase ACS355-03X-01A2-4 AC supply, 380 to 480 V.
    Typical motor ACS355-03X-01A2-4 power in 400 V at normal use: 0.37kw.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 1.2A.
    Frame size: R0.
    Current rating represents the rated continuous drive output current inside the drive specification.
    Typical motor power in 460 V at normal use: 0.5hp.
    This code states the factory installed SW variants to the drive.

  • Product Name: Inverter.
    Model: ACS355-03X-01A9-4.
    Typical ACS355-03X-01A9-4 motor power ACS355-03X-01A9-4 in 460 V at normal use: 0.75hp.
    Typical motor power in 400 V at normal use: 0.55kw.
    3-phase AC supply, 380 to 480 V.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 1.9A.
    Frame size: R0.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    This code states the factory installed SW variants to the drive.

  • Product Name: Inverter.
    Model: ACS355-03X-02A4-2.
    3-phase ACS355-03X-02A4-2 AC supply, 200 to 240 V.
    Typical motor ACS355-03X-02A4-2 power in 400 V at normal use: 0.37kw.
    Current rating represents the rated continuous drive output current inside the drive specification.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
    Frame size: R0.
    Typical motor power in 460 V at normal use: 0.5hp.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    This code states the factory installed SW variants to the drive.

  • Product Name: Inverter.
    Model: ACS355-03X-02A4-4.
    3-phase ACS355-03X-01A9-4 AC supply, 380 to 480 V.
    This code states the factory ACS355-03X-01A9-4 installed SW variants to the drive.
    Typical motor power in 460 V at normal use: 1.0hp.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
    Frame size: R1.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Typical motor power in 400 V at normal use: 0.75kw.

  • Product Name: Inverter.
    Model: ACS355-03X-03A3-4.
    3-phase ACS355-03X-03A3-4 AC supply, 380 to 480 V.
    Typical motor ACS355-03X-03A3-4 power in 400 V at normal use: 1.1kw.
    This code states the factory installed SW variants to the drive.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.3A.
    Frame size: R1.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Typical motor power in 460 V at normal use: 1.5hp.

  • Product Name: Inverter.
    Model: ACS355-03X-03A5-2.
    Current ACS355-03X-03A5-2 rating represents the rated continuous drive output current ACS355-03X-03A5-2 inside the drive specification.
    Typical motor power in 400 V at normal use: 0.55kw.
    Typical motor power in 460 V at normal use: 0.75hp.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.5A.
    Frame size: R0.
    3-phase AC supply, 200 to 240 V.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    This code states the factory installed SW variants to the drive.

  • Product Name: Inverter.
    Model: ACS355-03X-04A1-4.
    3-phase ACS355-03X-04A1-4 AC supply, 380 to 480 V.
    Typical motor ACS355-03X-04A1-4 power in 400 V at normal use: 1.5kw.
    This code states the factory installed SW variants to the drive.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
    Frame size: R1.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Typical motor power in 460 V at normal use: 2.0hp.

  • Product Name: Inverter.
    Model: ACS355-03X-04A7-2.
    3-phase ACS355-03X-04A7-2 AC supply, 200 to 240 V.
    Typical motor ACS355-03X-04A7-2 power in 400 V at normal use: 0.75kw.
    Typical motor power in 460 V at normal use: 1.0hp.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.7A.
    Frame size: R1.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    This code states the factory installed SW variants to the drive.

  • Product Name: Inverter.
    Model: ACS355-03X-05A6-4.
    ACS355 ACS355-03X-05A6-4 is available in two voltage ranges: 2 = 200 to 240 V and ACS355-03X-05A6-4 4 = 380 to 480 V.
    Typical motor power in 400 V at normal use: 2.2kw.
    Typical motor power in 460 V at normal use: 3.0hp.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.6A.
    Frame size: R1.
    Current rating represents the rated continuous drive output current inside the drive specification.
    3-phase AC supply, 380 to 480 V.
    This code states the factory installed SW variants to the drive.

  • Product Name: Inverter.
    Model: ACS355-03X-06A7-2.
    3-phase ACS355-03X-04A7-2 AC supply, 200 to 240 V.
    Typical motor ACS355-03X-04A7-2 power in 400 V at normal use: 1.1kw.
    This code states the factory installed SW variants to the drive.
    Continuous rms current. 50% overload is allowed for one minute in ten minutes: 6.7A.
    Frame size: R1.
    Current rating represents the rated continuous drive output current inside the drive specification.
    ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
    Typical motor power in 460 V at normal use: 1.5hp.