IC693ALG222 Analog Voltage Input Module

Compare

Description

IC693ALG222 Analog Voltage Input Module,Ge Plc 90-30 Cpu Parts,Rack
Adaptor Bracket,Ge Automation Controls,Ge Input Simulator Module
CPU PARTS Programmable PLC Communicate MODULES Robots DCS,Analog
Voltage Input – 16 Channel IC693ALG222 The 16-Channel Analog
Voltage Input module provides up to 16 single-ended or eight
differential input channels, each capable of converting an analog
input signal to a digital value for use as required by your
application. This module provides two input ranges: 0 to 10 V
(unipolar) 10 to +10 V (bipolar) Voltage Ranges and Input Modes The
default input mode and range is single-ended, unipolar, with the
user data scaled so that 0 volts corresponds to a count of 0 and 10
volts corresponds to a count of +32000. The other range and mode
are selected by changing the configuration parameters using the
Logicmaster 90-30/20/Micro or CIMPLICITY Control configurator
software, or the Hand-Held Programmer. The range can be configured
for bipolar 10 to +10 V where 10 V corresponds to a count of 32000,
0 V corresponds to a count of 0, and +10 V corresponds to a count
of +32000. High and Low alarm limits are available on all ranges.
Ranges can be configured on a per channel basis. Power Requirements
and LEDs This module consumes a maximum of 112 mA from the 5V bus
on the PLC backplane. It also requires a maximum of 41 mA from the
backplane Isolated+24 Volt DC supply to power the on-board power
converter that provides isolated 5V supplies to power the user-side
circuitry (see Table 3-9, Specifications). There are two green LED
indicators on the module which provide module and user supply
status. The top LED, MODULE OK provides module status information
on power-up as follows: ON: status is OK, module configured OFF: no
backplane power or software not running (watchdog timer timed out)
Continuous rapid flashing: configuration data not received from CPU
Slow flashes, then OFF: failed power-up diagnostics or encountered
code execution error The bottom LED, Power Supply OK, indicates
that the internally generated user-side +5V supply is above a
minimum designated level. Location in System This module can be
installed in any I/O slot of a 5 or 10-slot baseplate in a Series
90-30 PLC system. References Used The number of 16-Channel Analog
Voltage Input modules which may be installed in a system depends on
the amount of %AI and %I references available. Each module uses 1
to 16 %AI references (depending on the number of channels enabled)
and from 8 to 40 %I references (depending on alarm status
configuration). The available %AI references are: 64 with CPUs 311,
313, and 323; 128 with CPU331; 1024 with CPUs 340 and 341; and 2048
with CPUs 350 364. 10 10-10 Series 90-30 PLC I/O Module
Specifications July 2000 GFK-0898F The maximum number of 16-Channel
Analog Voltage Input modules which may be installed in a system
are: 4 in a system using CPUs 311, 313, or 323 8 in a system using
CPU331 12 in a system using CPUs 340 or 341 51 in a system using
CPUs 350 364 When planning the module configuration for your
application you must also consider the load capacity of the
installed power supply and the total load requirements of all
modules that are installed in the baseplate. Refer to the Series
90-30 Programmable Controller Installation Manual, GFK-0356 for
details on power supplies and module load requirements. Table 10-3.
Specifications for 16-Channel Analog Voltage Input Module,
IC693ALG222 Number of Channels 1 to 16 selectable, single-ended 1
to 8 selectable, differential Input Current Ranges 0V to +10V
(unipolar) or 10V to +10V (bipolar); selectable each channel
Calibration Factory calibrated to: 2.5 mV per count on 0V to +10V
(unipolar) range 5 mV per count on 10 to +10V (bipolar) range
Update Rate 6 msec (all 16 single-ended channels) 3 msec (all 8
differential channels) Resolution at 0V to +10V 2.5 mV (1 LSB = 2.5
mV) Resolution at 10V to +10V 5 mV (1 LSB = 5 mV) Absolute Accuracy
0.25% of full scale @ 25 C (77 F) 0.5% of full scale over specified
operating temperature range Linearity < 1 LSB Isolation 1500
volts between field side and logic side Common Mode Voltage
(Differential) 11V (bipolar range) Cross-Channel Rejection > 80
db from DC to 1 kHz Input Impedance >500K ohms (single-ended
mode) >1M ohms (differential mode) Input Filter Response 41 Hz
(single-ended mode) 82 Hz (differential mode) Internal Power
Consumption 112 mA (maximum) from the backplane +5 VDC bus 41 mA
(maximum) from the backplane Isolated +24 VDC supply Refer to
Appendix B for product standards and general specifications. The
summation of the differential input, common-mode voltage, and noise
must not exceed 11 volts when referenced to COM. In the presence of
severe RF interference (IEC 801-3, 10V/m), accuracy may be degraded
to 5% FS. Analog Input Modules 10 GFK-0898F Chapter 10 Analog Input
Modules 10-11 CPU Interface to the IC693ALG 222 Analog Voltage
Input Module The Series 90-30 PLC uses the data within the %AI data
table to record analog values for use by the programmable
controller. This scheme for the 16-Channel Analog Voltage Input
module is shown below. More information on the CPU interface to
analog modules can be found at the beginning of this chapter.
SERIES 90-30 CPU A/D CONVERTER DATA TABLE % AI USER CONNECTIONS
ANALOG VOLTAGE INPUT MODULE CHx MICRO PROCESSOR BACKPLANE INTERFACE
VLSI OPTO ISOLATION COM CHx (+) CHx+1 CHx ( ) 233K 233K 3300pf
3300pf + + 280K 280K a47042 NOTE: CHx AND CHx+1 INDICATE
SINGLE-ENDED MODE; CHx (+) AND CHx ( ) INDICATE DIFFERENTIAL MODE
Figure 10-9. 16-Channel Analog Voltage Input Module Block Diagram –
IC693ALG222 Placement of A/D Bits within the Data Tables Since
converters used in the analog modules are 12-bit converters, not
all of the 16 bits in the data tables contain data required for the
conversion. A version of the 12 bits is placed within the 16-bit
data word corresponding to the analog point (in the %AI table). The
Series 90-30 PLC system handles the integration differently for the
various analog modules. The CPU does not manipulate the data from
the input modules before placing it within the word in the %AI data
table. The bits in the %AI data table which were not used in the
conversion by the input module are either forced to 0 (zero) by the
analog input module. Placement of the 12 data bits from the A/D
converter for an analog current input data word for the 16-Channel
Analog Voltage Input module in unipolar range is shown below. X D11
D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 X X X MSB LSB X=not converted
bits Analog values are scaled over the range of the converter.
Factory calibration adjusts the analog value per bit (resolution)
to a multiple of full scale (that is, 2.5 mV/bit for unipolar; 5
mV/bit for bipolar). This calibration leaves a normal 12-bit
converter with 4000 counts (normally 212 = 4096 counts). The data
is then scaled with the 4000 counts over the analog range. For
example, the data to the A/D converter for the 16-Channel Analog
Voltage Input is scaled as shown below. 10 10-12 Series 90-30 PLC
I/O Module Specifications July 2000 GFK-0898F A/D BITS (decimal)
VOLTAGE; 0 to 10V RANGE a45717 0 10 0 4000 Figure 10-10. A/D Bits
vs. Voltage Input for IC693ALG222.

Product Details: Description:

IC693ALG222 Analog Voltage Input Module

Model Number:

IC693ALG222

Manufacturer(s) : GE Product Type:

Analog Voltage Input Module

Warranty: 1 Year Plance of Origin: Made in USA Estimated Shipping Size:

Dimensions: 1″ x 5″ x 5″ (4 cm x 13 cm x 13 cm)

Weight: 0 lbs 13 oz (0.36 kg)

IC693ALG222

Advantage brands :

GE

IC693CPU363,IC697PWR711,IC693CPU364,IC693,IC697,IC695,IS200,IS215,DS200…

Allen Bradley

1756-L62,1756-L63,1746,1747,1756,1769,1794,2711P..

SCHNEIDER

140CPU43412U,140CPU65150,140CPU65160,140CPU,NOE,CRA,CPS,BMX,TCSE….

ABB

DSQC(07KT98 WT98,07KT97 WT97,DSQC679,IMASI23,IMDSO14…)

Bently Nevada

3500/42M,3500/22M,3500/95.3500/15…

TRICONEX

3805E,3008,3504E,3624,3700A,3721,4351B,4119A.. ..

Siemens MOORE

6ES7(1.2.3.4),6ES5,6DD,6DP….

IC697CPM925

IC697CPU731

IC697CPU772

IC697CPU781

IC697CPU782

IC697CPX772

IC697CPX935

IC697CPX935-FD

IC697MDL240

IC697MDL250

IC697MDL350

IC697MDL653

IC697MDL740

IC697MEM715

IC693ALG442 As an Analog Current/Voltage Combination Input/Output
the GE Fanuc 90-30 IC693ALG442 provides up to 4 differential input
current or voltage channels and 2…
IC693APU300 High Speed Counter GE Fanuc 90-30 IC693APU300 is a
single-slot module which can be used in applications where pulse
input rates exceed the input capability of…
IC693APU301 The Motion Mate APM GE Fanuc 90-30 IC693APU301 is an
easy-to-use intelligent, fully programmable 1-axis motion control
module. The GE Fanuc 90-30 IC693APU301…
IC693APU302 The Motion Mate APM GE Fanuc 90-30 IC693APU302 is an
easy-to-use intelligent, fully programmable 2-axis motion control
module. The GE Fanuc 90-30 IC693APU302…
IC693APU305 An I/O Processo, the GE Fanuc 90-30 IC693APU305,
provides direct processing of rapid pulse signals for industrial
control applications. GE Fanuc 90-30…
IC693BEM320
The GE Fanuc 90-30 IC693BEM320 provides an interface between a
Series 90-30 PLC and a proprietary Fanuc I/O LINK in a Fanuc CNC
(Computer Numerical…

IC693BEM321 A GE Fanuc 90-30 IC693BEM321 is configured as a master
module on a proprietary Fanuc I/O LINK. GE Fanuc 90-30 IC693BEM321
can receive 1024 discrete inputs…
IC693BEM331 The GE Fanuc 90-30 IC693BEM331 provides the interface
between a Series 90-30 PLC and a Genius I/O serial bus. GE Fanuc
90-30 IC693BEM331 receives and…
IC693CBL300

}

}

}

China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

IC693ALG222 Analog Voltage Input Module Images

Reviews

There are no reviews yet.

Be the first to review “IC693ALG222 Analog Voltage Input Module”

Your email address will not be published. Required fields are marked *