Honeywell sieger sensepoint gas detectors, gas detection probe

Compare

Description

Category: the HONEYWELL gas detector Name: [ 123] the HONEYWELL gas detector model: Honeywell sieger sensepoint gas detectors, gas detection probe [ 123] whether to recommend: is inventory: 111 [ 123] product description:

Sensepoint combustible gas, toxic gas and oxygen detectors series, provide high-quality industrial gas needs of the user is detected, a low-cost solution. By using the corresponding authentication Exd or Exe junction box attached to the potentially explosive area. Sensepoint industry standards and outputs can be connected to a controller or a third party Honeywell Analytics DCS / PLE system. Flammable and toxic gas detectors have been the latest European ATEX safety and performance standards.

Sensepoint toxic gas sensors may be applied to a hazardous environment, see the technical description measurement range. Electrochemical technology, capable of accurately and stably detecting toxic gas concentration in the atmosphere, and explosion-proof junction box which can be used in the connection region d, inherently safe design with integrated sensors, with even before the end of life of the sensor, and to ensure rapid response. Sensepoint toxic gas sensor wiring for the two-wire 4-20mA, suitable for most industrial applications.

Sensor Type:…

a ammonia 0-50 / 100 / 1000ppm b Oxygen 0-25% VOL
c chlorine 0-5 / 15ppm d sulfide 0-50 / 100ppm [123. ] e. carbon monoxide 0-100 / 200 / 500ppm f. hydrogen 0-1000 / 10000ppm
g. sulfur dioxide 0-15 / 50ppm h. nitric oxide (nitrogen oxides) 0-100 / 500ppm
i. nitrogen dioxide 0-10ppm
Note: the host closed, re-opening the power, oxygen, chlorine, nitrogen dioxide, sulfur dioxide and ammonia will take some time to stabilize.

Standard M20 terminal box

Anti-hydrocarbon (oil) vapor filter layer

SENSEPOINT sensor

M20 thread

shield

sensor serial number / date of manufacture

EXD / E waterproof connector

Technical parameters:

Operating temperature: -25 ℃ ~ + 50 ℃ humidity: 10-99% RH

preheating time: 3 minutes less than
response time: less than 5 seconds T20, T50 is less than 12 seconds, T90 is less than 30 s
power supply: DC 18V ~ 30V, the maximum power consumption of 0.9 watts
output: 4-20mA linearity error: less than 5% of full scale
sensor life: over two years
zero drift: time: less than + 2% of full scale / year
temperature: less than + 5% of full scale
humidity: less than + 2% of full scale
sensitivity drift: time: less than + 4% of full scale / year
temperature : less than 2% of full scale +
humidity: less than 2% of full scale +
sensor weight: 185 g Junction box Weight: about 0.5 kg
structural material: polyester shell preservative
Protection: Standard IP65
IP66 / 67 (installation of shields)
Ex certification:
the CE Certification: [ 123]

optional Accessories:
the weather baffle
calibration cover
fittings for wall mounting pipe
collection hood

Reviews

There are no reviews yet.

Be the first to review “Honeywell sieger sensepoint gas detectors, gas detection probe”