Description
Honeywell Honeywell Impact / Impact Pro Aspirated Quad portable oxygen combustible gas detector capable of chlorine dioxide and displaying simultaneously monitor up to four gases. With high specification flammable gases, oxygen and patented gas sensor Surecell ™, our unique technology ensures that the probe can always secure, accurate and reliable measurements.
The detector has two available configurations, Impact / Impact Pro acceptable disposable and / or replaceable probe, respectively, which are pre-calibrated and can be replaced within 1 minute – in all possible place to simplify maintenance and minimize costs. Simple and durable, these monitors are designed for harsh operating environment, but at the same time without losing the small, lightweight and unobtrusive features, all of which makes them ideal for use in limited space access more difficult.
The detector detector designed to apply your desired job; before entering a limited space, inlet may be used, or a hand-held aspirator (Impact Pro as accessories for the standard supply) through an optional internal pump ( when connected to the sampling line, the pump will automatically open and close) perform inspection gas.
Honeywell Honeywell Impact / Impact Pro bright powerful warning lamp and audible alarm (coupling periodic blinking green and beep) provides a reliable detection of: monitoring the always in operation, and does not miss alarm. Meanwhile, for the environment in terms of noise, Impact Pro also comes standard with a vibration alarm. Large backlit display with multi-language visual menu system will not only make it easier and operator training to a minimum extent of use.
Honeywell Honeywell Impact / Impact Pro provides a variety of accessories including the unique Enforcer calibration system and compliance with standards Safelink communications system, you can be sure: Impact range of portable multi-gas monitors will be when you need it most Protect your ready.
Honeywell Honeywell Impact / Impact Pro Quad portable pump suction gas detector characteristics:
Features:
reliable operation
pre-calibrated sensor cartridge insertion
high-Sensor [123 ] Patent Surecell ™ gas sensors
stable and accurate
simple and practical
a button on / off
Four languages, visual menu system
screen prompts to guide the user [ 123] correction coefficient for the built-flammable gas
minimize training
to facilitate maintenance
plug-in operation, for all durable portion
be replaced within one minute of the probe
completed within two minutes using Enforcer recalibration
low acquisition cost
durable housing
rugged, shock
protection class IP67, weather protection
daily use e [ 123] alarm display
3 instantaneous level alarm, toxic gas alarm time averages
confidence periodic flashing and beeping
flashes rapidly increasing, bright alarm LED
strong dual front sound an audible alarm
check the user enter the danger zone
peak hold function and Inlet
handheld suction
optional built automatic pump
full flexibility
Honeywell Honeywell Impact / Impact Pro portable pump suction gas detector Quad technical parameters
use
of the user up to four gases hazardous working environment, protection of the portable pump gas detector.
Monitoring the gas
GAS, O2, CO, H2S, CO2, chlorine, nitrogen dioxide, ammonia, carbon dioxide.
User Interface
backlit display screen ultra-clear, intuitive key menu system.
Data Download
when the instrument supplierHas been set is ready for use, the Chinese standard data logger.
structure
durable plastic, antistatic EN50014.
Size
49mm x 84mm x 136mm (1.9 “x 3.3” x 5.3 “)
by weight
Maximum 520g (18oz) comprising a built-in rechargeable battery and optional pump.
IP grade
IP67 (NEMA 4 & 6)
Operating temperature
-20 ° C to + 55 ° C (-4 ° F to + 131 ° F.)
storage temperature
-40 ° C to + 80 ° C (-40 ° F to + 176 ° F)
humidity
20-90% continuous operation RH. brief work 0-99% RH non-condensing.
alarm
3 momentary alarm level. gas alarm time average.
is set in advance
(the user can PC software configuration of the base).
audible alarm
in case of failure emitted regular dual low beep alarm sound, alarm sound is 1 meter 85dBA (1 feet to 90dBA). [123 ]
video alarm
and the green lamp blinks red rapid fault, gas alarm and warning.
battery performance
Ni-MH> 10 hours (charge 7 hours). alkaline batteries > 17 hours. use the pump is turned on , Nominal reduction 10%.
is set within the pump
Impact Pro series as standard, typically the absorbent flow rate of 0.31 / min.
POST
Automatic Start / Stop , liquid can fault alarm.
security authentication
European: Ex II 2G, EEx ia d IIC T4 (ATEX)
USA
Class 1, Div 1, Groups A, B, C, D (UL)
Canada
Class 1, Div 1, Groups A, B, C, D (CSA)
Australia
(surface): Ex ia s Zone 0, I / IIB, T4 [123 ]
Australia
(mine): MDA GD 5053
Brazil
BR-Ex ia d IIC T4 (INMETRO)
ocean
Marine Equipment Directive MED